The QC Kit is a quality control tool for pipetting volume verification of your liquid handling platform, ensuring full regulatory compliance.
It consists of hardware, consumables and software, guides the user through the testing protocol, and provides CV and accuracy values for pipetting volumes.
***************************************************************************************
***************************************************************************************
Tab 01 / Quality and reliablility
***************************************************************************************
***************************************************************************************
The need for ever stricter quality control requires laboratories to perform regular quality checks on their assays and equipment, including their automated liquid handling workstations. Tecan has addressed this need by introducing the QC Kit, allowing quick and comprehensive volume transfer verification for Freedom EVO and Fluent workstations.
The QC Kit saves time compared to other methods because there is no need for sample preparation, standard curve generation or post-measurement calculations. On completion of a test, a report with clear pass/fail indications is generated automatically.
Step-by-step software guidance, with clear instructions, eliminates mistakes and ensures that this method is suitable for technicians of any skill level.
Test results based on the QC Kit are traceable to international standards and can be compared to manufacturers’ specifications for IQ/OQ. In addition to pass/fail indications, overall accuracy and volume per tip information is displayed on the printout.
The QC Kit incorporates Artel’s proprietary Ratiometric Photometry technology onto Freedom EVO and Fluent systems. In the first step, the blue diluent solution is dispensed into the well of the dimensionally-characterized QC Kit verification plate.
Read moreIn order to correct for day-to-day performance variations in the QC Kit reader, and to allow direct comparison of instrument performance, the absorbance measurements are normalized using a calibrator plate. This allows the readings to be directly correlated a reference spectrophotometer, in accordance with the requirements of ISO/IEC 17025 and ANSI/NCSL Z540 standards.
Read moreQC Kit verification plates are fully characterized 96- and 384-well format microplates. Dimensional and performance characterization of the QC Kit verification plates, solutions and calibrator plates using certified reference materials offers full traceability of results to the International System of Units (SI).
Read moreTecan offers a broad range of QC Kit solutions to cover volume ranges from 100 nl to 200 µl in 96-well format, and 30 nl to 55 µl in 384-well format. QC Kit solutions are characterized lot-by-lot by Artel, using a reference spectrophotometer to achieve full traceability of results to the International System of Units (SI).
Read more
***************************************************************************************
***************************************************************************************
Tab 02 / Videos
***************************************************************************************
***************************************************************************************
***************************************************************************************
***************************************************************************************
Tab 03 / Literature
***************************************************************************************
***************************************************************************************
Overview of the QC Kit: benefits, components and technology.
Reliable assay results and maximized productivity with Tecan’s quality consumables.
***************************************************************************************
***************************************************************************************
Tab 04 / Request a Quote!
***************************************************************************************
***************************************************************************************
384 well verification plates for QC Kit
For verification of liquid handling performance for QC Kit. 25 plates/sales unit.
96 well verification plates for QC Kit
For verification of liquid handling performance for QC Kit. 25 plates/sales unit.
Baseline solution for QC Kit
Required for baseline measurement prior to verification testing. 1 bottle/sales unit (220 mL).
Diluent solution for QC Kit
Required for verification testing with QC Kit. 1 bottle/sales unit (500 mL).
Range A sample dye solution for QC Kit
96-well volume range: 50-200 µL, 384-well volume range: 10-55 µL. 1 bottle/sales unit (110 mL).
Range B sample dye solution for QC Kit
96-well volume range: 10-49.99 µL, 384-well volume range: 2.5-9.99 µL. 1 bottle/sales unit (110 mL).
Range C sample dye solution for QC Kit
96-well volume range: 2.0-9.99 µL, 384-well volume range: 0.5-2.499 µL. 1 bottle/sales unit (110 mL).
Range D sample dye solution for QC Kit
Range D sample dye solution for QC Kit, 96-well volume range: 1.0-1.99 µL, 384-well volume range: 0.20-0.499 µL. 1 bottle/sales unit (110 mL).
Range E sample dye solution for QC Kit
96-well volume range:0.1-0.99 µL, 384-well volume range: 0.03-0.299 µL. 1 bottle/sales unit (110 mL).